Compressed Air Pipe Pressure Drop Calculator
Δp =
450 × ( V / 0.06 )1.85 × L
d5 × Pmax
Δp: Pressure drop (bar)
V: Total air flow rate (m³/min)
L: Total pipe length (m)
Pmax: Maximum operating pressure (bar)
d: Internal pipe diameter (mm)
Enter air flow rate, pipe length, operating pressure, and internal diameter to calculate the pressure drop along the pipeline (bar).
Enter the flow rate in liters per second (l/s). The value will be automatically filled into the m³/min field below.
Calculation Result
Pressure drop along the pipeline: 0 bar
The calculated Δp is an estimation based on an empirical formula and does not account for temperature variation, pipe roughness, humidity, or air quality. A suitable design safety margin is recommended.
Common PU Flexible Hose Dimensions
| Type | Outer Diameter OD (mm) | Inner Diameter ID (mm) | Wall Thickness (mm) |
|---|---|---|---|
| PU 3.2 × 2.0 | 3.2 | 2.0 | 0.60 |
| PU 4 × 2.5 | 4.0 | 2.5 | 0.75 |
| PU 6 × 4 | 6.0 | 4.0 | 1.00 |
| PU 8 × 5 | 8.0 | 5.0 | 1.50 |
| PU 10 × 6.5 | 10.0 | 6.5 | 1.75 |
| PU 12 × 8 | 12.0 | 8.0 | 2.00 |
| PU 16 × 11 | 16.0 | 11.0 | 2.50 |