Compressed Air Pipe Pressure Drop Calculator

Δp =
450 × ( V / 0.06 )1.85 × L
d5 × Pmax

Δp: Pressure drop (bar)

V: Total air flow rate (m³/min)

L: Total pipe length (m)

Pmax: Maximum operating pressure (bar)

d: Internal pipe diameter (mm)

Enter air flow rate, pipe length, operating pressure, and internal diameter to calculate the pressure drop along the pipeline (bar).

Enter the flow rate in liters per second (l/s). The value will be automatically filled into the m³/min field below.

If your flow unit is different (l/s, CFM, etc.), please use the conversion box above.

Including equivalent length of valves, elbows, tees, etc.
➜ Equivalent length table for compressed air fittings

➜ Pressure unit converter (bar, Pa, psi…)

You may enter the internal diameter manually, select a DIN 2440 steel pipe DN, or select a PU hose size to auto-fill the standard internal diameter.

Common PU Flexible Hose Dimensions

TypeOuter Diameter OD (mm)Inner Diameter ID (mm)Wall Thickness (mm)
PU 3.2 × 2.03.22.00.60
PU 4 × 2.54.02.50.75
PU 6 × 46.04.01.00
PU 8 × 58.05.01.50
PU 10 × 6.510.06.51.75
PU 12 × 812.08.02.00
PU 16 × 1116.011.02.50